1. Home
  2. /
  3. Products
  4. /
  5. Flowmeters
  6. /
  7. Flowmeters – Type 785

Typ_785_100_01Flowmeter according to the variable area principle for liquids

TECHNICAL DATA

Temperature Range:

  • tube material: trogamid = 60 °C
  • tube material: polysulfon = 60 °C
  • end connections: uPVC = 100 °C
  • end connections: malleable iron = 100 °C
  • end connections: stainless steel = 100 °C 

O-Ring Seals: EPDM or FPM 

Float Material: stainless steel, stainless steel with magnet.

Accuracy Class: 2,5 according to VDE/VDI 3513 sheet 2 e.g. +/- 0,625 % of end-scale, +/- 1,875 % of measured value, inaccuracy in l/hr resp. m³/hr.

Maximum Pressure:

  • trogamid with PVC end connections: 10 bar
  • polysulfon with metal and connections: 16 bar

Standard Scales: l/hr and m³/hr based on water at 20 °C or scale. Special scales available on request.

Limit Switches (K) and Transmitter (FG): Limit switches or a continuous transmitter may be fitted to the flowmeter tube. When these accessories are used, a magnetic floater must also be used Installation Details: Controlled system: when the flowmeter is used in a system with valve control the following criteria must be observed:

  • with liquid flows the valve can be fitted before or after the flowmeter
  • with gases, the valve must be fitted after the flowmeter